Tekmar 260 Boiler Control One Stage & DHW

Product highlights:
  • 1 stage
  • Boiler differential (Automatic Adjustment / Manual)
  • Boiler minimum supply (Manual)
  • Characterized heating curve
  • Boiler outdoor reset
  • Availability: In Stock. Ships within 2-3 days.
  • MSRP:
  • Savings:
  • $700.82
  • $260.83
Price: $439.99
Free Shipping

QTY:

Boiler Control One Stage & DHW - Tekmar 260

The Boiler Control 260 is designed to operate a single boiler using outdoor reset. It can be used in applications ranging from baseboard or mixed radiant heating systems, to combination space heating and domestic hot water heating installations. This control regulates a single heating water temperature through outdoor reset and/or Domestic Hot Water control. It is capable of controlling a single on/off boiler and can receive both space heating and/or DHW heat demands.

Applications

  • One stage boiler with outdoor reset and multiple zones controlled by thermostats and zone valves
  • One stage boiler with outdoor reset and multiple zones controlled by thermostats and zone valves. Indirect DHW tank controlled by an aquastat and a zone valve
  • One stage boiler with outdoor reset and multiple zones controlled by thermostats and zone valves. Indirect DHW tank controlled by an aquastat and a zone pump with optional DHW priority
  • One stage boiler with outdoor reset and multiple zones controlled by thermostats and zone pumps. Indirect DHW tank controlled by an aquastat and a zone pump with optional DHW priority

Control Functions - Boiler Operation

  • 1 stage
  • Boiler differential (Automatic Adjustment / Manual)
  • Boiler minimum supply (Manual)
  • Characterized heating curve
  • Boiler outdoor reset
  • Boiler post purge (Fixed)
  • Fire delay (Manual)
  • Heating curve shift (Automatic / Manual)
  • Indoor temperature feedback
  • Warm weather shut down
  • Water temperature Boost (Automatic Adjustment)

Domestic Hot Water (DHW) Operation

  • DHW boiler reset override
  • DHW Condensing Boiler
  • DHW external demand
  • DHW post purge
  • DHW priority
  • DHW setback

Setpoint Operation

  • Setpoint boiler reset override
  • Setpoint priority

Protection

  • Pump excercising

Setback

  • Timer, 7 day
  • Water temperature boost (indoor feedback)
  • Water temperature setback
  • Zone temperature setback

Display

  • Temperature display

Application:
Single Boiler
Depth (Inch):
2-13/16
Width (Inch):
7-9/16
Height (Inch):
6-5/8
User Interface:
Push Button
Temperature Range (°F):
-67°-266°F
Voltage (V):
240V